Accusys RAID Controller ACS-77100 Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
http://www.accusys.com.tw
12
User’s Manual
3.1.1 RAID Level configurations
RAID Level 5 RAID Level 0
Pin1-3 is open.
Pin5-7 is open.
Pin1-3 is short.
Pin5-7 is short.
RAID Level 10 RAID Level 5 + spare
Pin1-3 is short.
Pin5-7 is open.
Pin1-3 is open.
Pin5-7 is short.
Note
If the RAID level is not matched between the disk setting and the RAID level
selector setting, the LCD will display the following two messages alternatively:
(1) “RAID level”
“Unmatched”
(2) “Current: R(X)” (i.e. the current RAID level setting of RAID level selector.)
“Original: R(Y)” (i.e. the original RAID level setting of the installed disks.)
Solution:
At this situation, RAID cannot work, users should choose one of the following
options :
(1) Shut down and tune the RAID level selectors to R(Y).
(2) Re-plug the four disks and re-create the Array to R(X). (But data in the RAID
will be lost due to the destructive initialization
)
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 29 30

Commentaires sur ces manuels

Pas de commentaire